Troubleshooting
How To: Factory Reset
-
To factory reset the board with BAM navigate to the System tab and select Reset All Settings. The board will require a manual reset afterwards.
-
The BAC may also be factory reset using the onboard buttons. Reset the board using the reset button and hold the input 0 button. After a few seconds the stat LED will start to flicker rapidly. Continue holding the button down until the flickering stops and then release. Press the input 0 button twice within three seconds to confirm. If performed correctly the STAT led will blink to indicate a successful factory reset. The BAC does not need a manual reset if the factory reset is performed this way.
Issue: Device Not Discovered in BAM
Ensure both ends of the ethernet cable are fully seated. Connect the BAC to a switch / router, not directly to a PC. Ensure your local network has DHCP capability if you are using DHCP settings (on by default).
Issue: Status LED continues to "breathe" on startup
bad flash